Nodweddion strwythurol
● Math o daflen bimetallig tri cham
● Gyda dyfais gymwysadwy barhaus ar gyfer gosod cyfredol
● Gyda iawndal tymheredd
● Gyda chyfarwyddiadau gweithredu
● Mae ganddo sefydliad profi
● Mae ganddo fotwm stopio
● Gyda botymau ailosod llaw ac awtomatig
● Gydag un y gellir ei wahanu'n drydanol, un ar agor fel arfer ac un cyswllt sydd wedi'i gau'n gyffredin
Nodwedd Dechnegol
Math | Cerrynt graddedig yr uned daith Yn(A) | Gosod yr ystod addasu gyfredol (A) | Cynhwysedd torri cylched byr eithaf lcu (kA), gallu torri cylched byr gweithredu graddedig lcs (kA) | Pellter arcing (mm) | |||||||||
230/240V | 400/415V | 440V | 500V | 690V | |||||||||
Icu | Ics | Icu | Ics | Icu | Ics | Icu | Ics | Icu | Ics | ||||
0.16 | 0.1-0.16 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 | |
0.25 | 0.16-0.25 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 | |
JGV2-32 | 0.4 | 0.25-0.4 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
0.63 | 0.4-0.63 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 | |
1 | 0.63-1 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 | |
1.6 | 1-1.6 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 | |
2.5 | 1.6-2.5 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 3 | 2.25 | 40 | |
4 | 2.5-4 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 3 | 2.25 | 40 | |
6.3 | 4-6.3 | 100 | 100 | 100 | 100 | 50 | 50 | 50 | 50 | 3 | 2.25 | 40 | |
10 | 6-10 | 100 | 100 | 100 | 100 | 15 | 15 | 10 | 10 | 3 | 2.25 | 40 | |
14 | 9-14 | 100 | 100 | 15 | 7.5 | 8 | 4 | 6 | 4.5 | 3 | 2.25 | 40 | |
18 | 13-18 | 100 | 100 | 15 | 7.5 | 8 | 4 | 6 | 4.5 | 3 | 2.25 | 40 | |
23 | 17-23 | 50 | 50 | 15 | 6 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 | |
32 | 24-32 | 50 | 50 | 15 | 6 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 | |
JGV3-80 | 40 | 25-40 | - | - | 35 | 17.5 | - | - | - | - | 4 | 2 | 50 |
63 | 40-63 | - | - | 35 | 17.5 | - | - | - | - | 4 | 2 | 50 | |
80 | 56-80 | - | - | 35 | 17.5 | - | - | - | - | 4 | 2 | 50 |
Pŵer graddedig y modur tri cham a reolir gan y torrwr cylched (gweler Tabl 2)
Math | Cerrynt graddedig yr uned daith Yn(A) | Amrediad addasu cyfredol graddedig (A) | Pŵer gradd safonol modur tri cham (kW) | |||||
AC-3, 50Hz/60Hz | ||||||||
230/240V | 400V | 415V | 440V | 500V | 690V | |||
0.06 | 0.1-0.16 | - | - | - | - | - | - | |
0.25 | 0.6-0.25 | - | - | - | - | - | - | |
JGV2-32 | 0.4 | 0.25-0.4 | - | - | - | - | - | - |
0.63 | 0.4-0.63 | - | - | - | - | - | 0.37 | |
1 | 0.63-1 | - | - | - | 0.37 | 0.37 | 0.55 | |
1.6 | 1-1.6 | - | 0.37 | - | 0.55 | 0.75 | 1.1 | |
2.5 | 1.6-2.5 | 0.37 | 0.75 | 0.75 | 1.1 | 1.1 | 1.5 | |
4 | 2.5-4 | 0.75 | 1.5 | 1.5 | 1.5 | 2.2 | 3 | |
6.3 | 4-6.3 | 1.1 | 2.2 | 2.2 | 3 | 3.7 | 4 | |
10 | 6-10 | 2.2 | 4 | 4 | 4 | 5.5 | 7.5 | |
14 | 9-14 | 3 | 5.5 | 5.5 | 7.5 | 7.5 | 9 | |
18 | 13-18 | 4 | 7.5 | 9 | 9 | 9 | 11 | |
23 | 17-23 | 5.5 | 11 | 11 | 11 | 11 | 15 | |
32 | 24-32 | 7.5 | 15 | 15 | 15 | 18.5 | 26 | |
JGV3-80 | 40 | 25-40 | - | 18.5 | - | - | - | 30 |
63 | 40-63 | - | 30 | - | - | - | 45 | |
80 | 56-80 | - | 37 | - | - | - | 55 |
Y lefel amddiffyn amgaead yw: IP20;
Perfformiad gweithredu'r torrwr cylched (gweler Tabl 3)
Math | Inm(A) cyfredol â sgôr ffrâm | Cylchoedd gweithredu fesul awr | Amseroedd cylch gweithredu | ||
Ups pŵer | Dim pŵer | Cyfanswm | |||
1 | 32 | 120 | 2000 | 10000 | 12000 |
2 | 80 | 120 | 2000 | 10000 | 12000 |
Amlinelliad a Dimensiwn Mowntio
Ffordd cludo
Ar y môr, mewn awyren, gan gludwr cyflym
FFORDD TALU
Gan T / T, (30% rhagdaledig a bydd y balans yn cael ei dalu cyn ei anfon), L / C (llythyr credyd)
Tystysgrif